5.
Initial Operation
5.3
Allocation of connections for command
and safety devices
Command and safety devices can be connected to terminals
X3, X4 and X5.
Terminal block X3
10
- CLOSE switch
9
8
- impulse switch
7
6
- OPEN switch
5
4
- STOP switch
3
2
- Emergency off, slack rope
1
switch, wicket door contact,
draw-in protection
Terminal block X4
(for optoelectronic safety edge protection)
10
9
wt
8
0 V
gr
7
Signal
br
+12 V
6
5
4
3
-
2
+
1
sequence control
1
button or selector switch
2
effective in down direction
3
for external switching devices
4
(connection to terminals 1 and 2)
wt:
white
gr:
green
br:
brown
– CS 300 Gate Controls / Rev. 5.3
1
- PART – OPEN
2
- safety edge protection
OPTO
- photoelectric
drive-through barrier
3
- 24 V DC / 250 mA
4
Terminal block X4
(for 8.2 kOhm safety edge protection)
10
- PART - OPEN
9
8
7
6
- safety edge protection
5
8,2 KOhm
4
- photoelectric drive-through
3
barrier
-
2
+
1
- 24 V DC / 250 mA
Terminal block X4
(for pneumatic safety edge protection – pressure sensor test:
- A 8.2 kOhm resistor must be connected in series
- The input point pressure sensor TEST must be switched on)
10
- PART - OPEN
9
8
7
6
8,2 KOhm
- safety edge protection
5
4
- photoelectric drive-through
3
barrier
-
2
+
1
- 24 V DC / 250 mA
Terminal block X5
(potential free switch contact)
1
- relay 1
2
3
- relay 2
4
5
- relay 3
6
7
- relay 4
8
2
3
4
2
3
4