5.

Initial Operation

5.
General
Warning!
To guarantee that the equipment
functions properly, the following points must
be ensured:
- The gate or door is installed and ope
rational.
- The drive motor is installed and
ready for operation.
- The command and safety devices are
installed and ready for operation.
- The control housing with the CS 300
control is installed.
Information:
For the installation of the gate/door,
the drive motor and the command and safety
devices, the relevant manufacturer's instruc-
tions are to
be adhered to.
5.
Mains connection
Danger!
To guarantee that the controls function pro-
perly, the following points must be ensured:
- The mains voltage must correspond
to the voltage stated on the type
plate.
- For a three-phase current, a
clockwise rotating field is required.
- For a permanent connection, an
all-pole main switch must be used.
- For a three-phase connection, only
3-way automatic circuit breakers
(10A) may be used.
Warning!
Before switching on the controls for the first
time, a check must be carried out after com-
pleting the wiring to ensure that all the motor
connections at the motor and at the controls
are securely fixed. All control voltage inputs
are galvanically isolated from the supply.
For all components to be connected to the
controls, at least one additional isolation with
a rated voltage of > 230V is recommended.
Detailed circuit diagram for mains connection and
motor
X11
M1
X2
K2
K1
Key:
K1:
protection, CLOSE
K2:
protection, OPEN
M1:
motor
T1:
transformer
X1:
terminal block for mains connection
X2:
terminal block for motor
X11:
sockets for digital end position system with safety
circuit (STOP CIRCUIT)
Connection:
Connect the digital end-position system to the control.
Connect the control to the mains.
Connect the control to the motor.
Short before the corresponding screw terminals, groups of
cables should be make safe by means of straps
Information:
Technical data see page 19.
CS 300 Gate Controls / Rev. 5.3 – 5
GB
GB
T1
400V/50Hz/3/N/PE
X1