Chamberlain Garos CS 300 Operating Instructions Manual page 41

Gate controls
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 26
.3
Diagnostic operating mode
Display
Meaning
ES-OPEN
OPEN end position
ES-CLOSE
CLOSE end position
OPEN BUTTON
OPEN button
PART OPEN
PART OPEN button (X4 / 9 + 10)
CLOSE BUTTON
CLOSE button
SEP
Safety edge protection
IMPULSE
Impulse button
TIMER
Weekly timer
P/E BARRIER
Photoelectric drive-through barrier
STOP CIRCUIT
- Stop button of controls
- Stop systems of drive
CYCLE
Gate-cycle counter
AVE
Absolute value encoder
Status
OFF:
confirmed
ON:
not confirmed
OFF:
confirmed
ON:
not confirmed
ON:
confirmed
OFF:
not confirmed
ON:
confirmed
OFF:
not confirmed
ON:
confirmed
OFF:
not confirmed
ON:
system circuit is closed
OFF:
system is interrupted (fault)
ON:
confirmed
OFF:
not confirmed
ON:
confirmed
OFF:
not confirmed
ON:
circuit closed
OFF:
interrupted (fault)
ON:
circuit closed
OFF:
interrupted (fault)
Displays the gate cycles
Shows the gate position value
CS 300 Gate Controls / Rev. 5.3 - 