Chamberlain Garos CS 300 Operating Instructions Manual page 39

Gate controls
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 26
.
Input operating mode
Function
Description
DEUTSCH
Select the menu language
RUNNING
Monitoring the max. running time for an open and close movement
TIME
OPEN
After the door has opened, it runs in the CLOSE direction again after the set time has
TIME
elapsed.
Open time > 0 = impulse functions only work in OPEN direction
ADVANCE
The traffic light flashes before the door starts to move downwards.
WARNING
The programmed forewarning time is only active if the open time > 0 or if in radio-
TIME
impulse operating mode
TURNA-
Standing time at every change of direction
ROUND
TIME
MOD1-3
MOD1: in non-operative state OFF
RESTING
MOD2: in non-operative state ON
QUICK
ON:
The open time is cut short after the photoelectric barrier has been passed
CLOSE
(door closes immediately)
OFF:
The open time continues as usual
RELAY 1
All 4 relays can be allocated to a relais mode of 1-18
MOD1:
Red lights while the gate moves and flashing in prewarning mode
MOD2:
Red lights are flashing while the gate moves and flashing in prewarning
MOD3:
Red lights while the gate moves and in prewarning
RELAY 2
The parameter M1-3 non-operative state takes effect at these 3 MOD
MOD4:
Impulse at OPEN order
MOD5:
Error message
MOD6:
OPEN end position
MOD7:
CLOSE end position
RELAY 3
MOD8:
Final position OPEN denied
MOD9:
Final position CLOSED denied
MOD10:
Before-end position OPEN
MOD11:
Before-end position CLOSE
MOD12:
From before CLOSE position to CLOSE position
MOD13:
Magnetic locking function
MOD14:
Brake
MOD15:
Brake negated
RELAY 4
MOD16:
Brake remains ON during open time
MOD17:
Brake remains ON in open time and while changing direction
(in SKS, brake falls down)
Setting options
Factory setting
DEUTSCH
DEUTSCH
ENGLISH
FRANCAIS
ESPANOL
NEDERLANDS
POLSKI
CESKY
ITALIANO
1 – 250 Seconds
60 Seconds
0 – 600 Seconds
0 =
Auto-close off
0 - 120 Seconds
0 = Off
0,1 - 2,0 Seconds (in
0,3 Seconds
1/10 Sec)
MOD1
MOD1
MOD2
ON
OFF
OFF
MOD1 - MOD17
MOD6
MOD1 - MOD17
MOD7
MOD1 - MOD17
MOD1
MOD1 - MOD17
MOD14
CS 300 Gate Controls / Rev. 5.3 - 5
GB

Advertisement

Table of Contents
loading