Qpc43 Peripheral Signaling Card - Nortel Meridian 1 Hardware Replacement Manual

Table of Contents

Advertisement

Page 218 of 250

QPC43 Peripheral Signaling Card

553-3001-520 Standard 17.00 January 2002
Replacing equipment
b.
Push the grill into a locked position against the pedestal.
c.
If there are captive screws on the grill, tighten the screws.
Use this procedure to replace a peripheral signaling card.
See Administration (553-3001-311) for a description of all maintenance
commands, and System Messages Guide (553-3001-411) for interpreting
system messages.
DANGER
Module covers are not hinged; do not let go of the
cover. Lift the cover away from the module and set it
out of your work area.
CAUTION
Service Interruption
Disabling or removing a peripheral signaling card
from a network shelf disables all loops on that shelf.
Removing equipment
1
Check the status of the peripheral signaling card:
LD 32
STAT PER x
a.
If the response is DSBL, go to See "Set the ENB/DIS switch to
DIS." on page 218..
b.
If the response is ENBL, enter DSPS x to disable the card, then
go to Step 2 on page 218.
2
Set the ENB/DIS switch to DIS.
3
Unhook the locking devices on the card; pull it out of the card cage.
Table 6 on page 220 lists peripheral signaling
card numbers specified by "x"

Advertisement