Completing the upgrade

1
Log into the system.
2
Verify CPU and CNI functionality:
LD 135
STAT CPU
STAT CNI
****
Make a backup of the customer database on 2MB diskettes:
3
Load the Equipment Data Dump Program (LD 43). At the prompt, enter
LD 43
4
When "EDD000" appears on the terminal, enter
EDD
5
When "DATADUMP COMPLETE" and "DATABASE BACKUP
COMPLETE" appear on the terminal, enter
****
6
Evaluate the number of call registers and telephone buffers that are
configured for the system. Refer to Capacity Engineering
(553-3001-149).
The card replacement procedure is complete.
Replacing equipment
to load the program
to check the CPU status
to verify CNI functionality
to exit the program
to load the program
to begin the data dump
to exit the program
CAUTION
System Failure
If the data dump is not successful, do not continue;
contact your technical support organization. A data
dump problem must be corrected before proceeding.
Page 101 of 250
Hardware Replacement