Page 48 of 250
Replacing equipment
553-3001-520 Standard 17.00 January 2002
8
Install the replaced NT4N68 SYS UTIL TRANS card.
9
Gently push the latches forward to set the card and lock it in place
CAUTION
Damage to Equipment
Never force the card into the slot. It the card gets
stuck, remove it and try again.
10
Use a small-bladed screwdriver to replace the screws on the SYS UTIL
TRANS cards.
11
Replace the cables and security device connections to the faceplate of
the SYS UTIL TRANS card.
12
Reseat the SYS UTIL card and push the latches to set the card into the
backplane connector.
13
At the front of the module, hardware enable the NT4N67 System Utility
card: set the faceplate switch to ENB.
14
In LD 135, on the inactive CP, software disable the SYS UTIL card:
ENL SUTL c
15
15
In LD 135, on the inactive CP, check the SYS UTIL card status:
STAT SUTL c
15
16
On the active CP, rejoin the two CP PII cards:
LD 135
JOIN
Enable the SYS UTIL card, where:
c = Core number (0 or 1)
This software enables both the cCPI System
Utility card and its associated cCPI System
Utility Transition card.
Disable the SYS UTIL card, where:
c = Core number (0 or 1)
This checks the status of both the cCPI System
Utility card and its associated cCPI System
Utility Transition card.
To load the program.