MAINTENANCE
2.
Blow the mud, dirt, or leaves if they are clogging the air
conditioner condenser fin (A), fuel cooler fin (B), aftercool-
er fin (C), oil cooler fin (D), radiator fin (E). Clean the net in
front of the oil cooler and aftercooler at this time.
REMARK
Remove the plate (5). Clean the radiator fin (E), oil
cooler fin (D) by using the L-shape cleaning tool as
shown in the figure.
(a): Air
(b): Nozzle
(c):300 mm
(d):300 to 500 mm
(e):160 mm
Steam or water may be used instead of compressed
air, but keep a distance from the fin.
Ask your Komatsu distributor for cleaning if the radia-
tor fin (E) and oil cooler fin (D) are grossly dirty.
You can clean it by rotating the fan in reverse.
Aftercooler fan does not have the fan reverse function.
For the method of the fan reverse mode, see "RE-
VERSE HYDRAULIC FAN".
3.
Remove the plates (6), (7), (8) and undercovers (9), (10),
and (11) to sweep out the mud, dirt, and leaves to the out-
side of the machine.
4.
Check the rubber hoses. If any hose is cracked or hard-
ened by age, replace with a new one. Also check and
tighten all loose hose clamps.
MAINTENANCE PROCEDURE
4-49