OPERATION
When the degree of urgency is high
KDPF soot accumulation caution lamp (2) lights up in red,
and "L03" is displayed in red on the action level display (3).
If the lock lever is set to LOCK position or all the work
equipment control levers are set in NEUTRAL, the screen
changes to "Aftertreatment Devices Regeneration" screen
(C) after 3 seconds. Then, the "Aftertreatment Devices Re-
generation" screen (C) and the standard screen (D) are
automatically displayed alternately according to the lever
operation, until the manual stationary regeneration is per-
formed.
If the KDPF soot accumulation caution lamp (2) lights up in
red, immediately stop the machine in a safe place and per-
form the manual stationary regeneration.
PROCEDURE FOR MANUAL STATIONARY REGENERATION
k
k
Exhaust gas temperature may become higher than the pre-
vious models during the aftertreatment devices regenera-
tion. Avoid getting near the exhaust pipe outlet and around
the aftertreatment devices to prevent being burnt. Also, do
not bring any combustible material close to the outlet of
the exhaust pipe or the aftertreatment devices to prevent a
fire.
The manual stationary regeneration can be performed while
the KDPF soot accumulation caution lamp (1) is lit.
1.
Move the machine to a safe place and stop it while the en-
gine is running.
2.
Check that there is no person or combustible matter
around the machine (particularly in the direction of the ex-
haust gas flow).
3.
Operate the operating portion (g) of the lock lever to set it
securely to LOCK position (L).