Components - Siemens SIMOTION P320-3 Manual

With panel fronts
Table of Contents

Advertisement

Description
2.2 SIMOTION P structure
2.2.3

Components

The most important components of a SIMOTION P application are listed below, along with
their function.
Distributed I/O systems (PROFINET)
Table 2- 1
Component
SIMATIC ET 200M
SIMATIC ET 200S
SIMATIC ET 200eco
SIMATIC ET 200pro
Note
Please note that not all modules of the above-mentioned I/Os or I/O systems are approved
for SIMOTION. Moreover, system-related functional differences can occur when these I/O or
I/O systems are used on SIMOTION vs. on SIMATIC. For example, special process-control
functions (hot swapping, etc.) are not supported by SIMOTION for the ET 200M distributed
I/O system.
For a detailed and routinely updated list of I/O modules enabled with SIMOTION as well as
application information, visit us online at:
Siemens - Industry Automation and Drive Technologies - Service & Support
(http://support.automation.siemens.com/WW/view/en/11886029)
Further modules are integrated via the GSD file of the device's manufacturer.
Note
Please note that in individual cases, additional general conditions must be fulfilled.
Drive systems (via PROFINET IO)
Table 2- 2
Component
SINAMICS S120
24
Components for distributed I/O
Function
Modular I/O system for control cabinet installation and high channel density.
Highly modular I/O system for control cabinet installation including motor
starters, safety technology, and individual grouping of the load groups.
I/O system with IP67 degree of protection for machine-related, cabinet-free
applications, featuring a flexible and fast connection system in ECOFAST or
M12.
Modular I/O system with IP65/67 degree of protection for machine-related,
cabinet-free applications, including motor starters.
List of typically connected drive systems
function
Servo drives, innovative single-axis and multi-axis solution
SIMOTION P320-3 and Panel Fronts