Siemens SIMOTION P320-3 Manual page 129

With panel fronts
Table of Contents

Advertisement

Environmental conditions
Ambient temperature
Humidity class
Degree of protection (EN 60529)
Radio suppression level (EN 55022)
Supply harmonics limitation according to
EN 61000-3-2
EMC immunity
EMC interference emission
Safety
Protection class (IEC 536; VDE 1006 T1)
Primary/secondary galvanic isolation
Dimensions and weight
Dimensions (W x H x D) in mm
Weight
Certifications and approvals
CE
UL/CSA
Shipbuilding
Directive 94/9/EC
C-Tick
Order numbers
SIMOTION P320-3 and Panel Fronts
Manual, 02/2012
During storage and transportation
During operation
–40° to +85° C
0° to +60° C
Climate class 3K3 acc. to EN 60721;
relative atmospheric humidity 5 to 95%;
no condensation
IP20
Class B
No
EN 61000-6-2;
EN 61000-4-2/-3/-4/-5/-6/-11
EN 61000-6-4
Class I
SELV output voltage acc. to EN 60950 and EN 50178;
transformer acc. to EN 61558-2-17;
overvoltage protection in the event of an internal fault
U
< 60 V
a
70 x 125 x 125
Approx. 0.75 kg
CE conformity acc. to 98/336 EEC and 73/23 EEC
UL 508 (Listed, File E197259);
CSA C22.2 No. 14, No. 60950-1-03
Germanischer Lloyd
Declaration of conformity acc. to EN 60079-15:
ATEX94/9/EC Cat.3;Eex, nA, II, T4 U
AS/NZS 2064:1997
6EP1334-2AA01, 6EP1334-2BA01
Spare parts/Accessories
11.1 Power supply