5.
Disconnect the cable at VIDEO IN (JV01) on the PM00 board to terminate
video.
6.
Set switch S501 on the P500 board to the High position.
7.
Disconnect the AURAL LOOP on the back of the unit.
8.
Replace the top cover and screws and reconnect all cables removed in step 1.
Terminal Connections from TVM450S/TVM550S
to Jerrold MVP
See Figure 4-5 while reading this section.
Figure 4-5. Agile IRDII, TVM450S/TVM550S and Jerrold
1.
Connect the MVP IF OUT to the TVM450S/TVM550S VISUAL IN connector.
2.
Connect the MVP INTERCARRIER to the TVM450S/TVM550S 4.5 MHz
OUT connector.
3.
Connect the MVP VIDEO IN to the TVM450S/TVM550S VIDEO OUT con-
nector.
4.
Connect the TVM450S/TVM550S VIDEO IN to the receiver VIDEO OUT
connector.
5.
Connect the TVM450S/TVM550S Baseband Right/Left to the receiver
RIGHT/LEFT Audio terminals.
Modifications to TVM550II and TVM550IIS units are needed to be able to use
the Jerrold system. Call SCC Customer Service at 1-310 532-5300 Ext. 336.