The following table describes the regulatory DC power specifications for the Avaya Virtual Services
Platform 8000 Series switch. Note that regulatory power specifications are based on the maximum
rated capacity of the power supplies and are not based on typical power consumption, which is
typically lower.
Table 13: DC power specifications
Input Current:
Input Voltage (rms):
Power Consumption:
Temperature:
Inrush Current:
Turn on Condition:
Important:
12 V output rise time, from 10 to 90 percent, must be the maximum of 70 ms and monotonic under all
defined input and output conditions.
Efficiency:

Removing a power supply

You can hot swap power supplies while the switch is operational.
Procedure
1. Disconnect the power cord from the power supply.
2. Lift up the power supply handle so you can grasp it.
3. Push the spring latch to the left and use the power supply handle to pull the power supply
out of the chassis.
4. If you are replacing the power supply, see
install the filler panel.
November 2016
VSP 8000 Series
24–16 A
40.5 to 60 VDC
800 W maximum
Operating range: 0 to 50º C
Non-operating range: -40 to 70º C
50 A maximum
500 milliseconds maximum after application of DC
power
• 88% minimum at 100% load level
• 92% minimum at 50% load level
• 88% minimum at 20% load level
• 80% minimum at 10% load level
Installing a power supply