Installing the Avaya Virtual Services Platform 8000 Series
The following table describes the regulatory AC power specifications for the Avaya Virtual Services
Platform 8000 Series. Note that regulatory power specifications are based on the maximum rated
capacity of the power supplies and are not based on typical power consumption, which is typically
lower.
Table 10: AC power specifications
Input Current:
Input Voltage (rms):
Power Consumption:
Thermal Rating:
Inrush Current:
Turn on Condition:
Important:
12 V output rise time, from 10 to 90 percent, must be the maximum of 50 ms and monotonic under all
defined input and output conditions.
Efficiency:

AC power cord specifications

To connect AC power to the switch, you need an appropriate AC power cord as described in the
following table, also see the following table for plug specifications.
Table 11: International power cord specifications
Country and Plug Specification
Continental Europe:
• CEE7 standard VII male plug
• Harmonized cord (HAR marking on the outside of the cord
jacket to comply with the CENELEC Harmonized
Document HD-21)
United States of America, Canada, and Japan:
• NEMA5-15P male plug
• UL-recognized (UL stamped on cord jacket)
• CSA-certified (CSA label secured to the cord)
November 2016
VSP 8000 Series
9.9–4.79 A
100–240 V, 47–63 Hz
800 W maximum
2730 BTU/Hr maximum
40 A maximum
1 second maximum after application of AC power
70 percent minimum
Installing the Avaya VSP 8000 Series
Comments on this document? infodev@avaya.com
Specifications
• 220 or 230VAC
• 50 Hz
• Single phase
• 100 or 120VAC
• 50–60 Hz
• Single phase
Typical Plug
Table continues...