Download Print this page
Avaya VSP 8284XSQ-AC Quick Install Manual
Avaya VSP 8284XSQ-AC Quick Install Manual

Avaya VSP 8284XSQ-AC Quick Install Manual

Vsp 8000 series virtual services platform
Hide thumbs Also See for VSP 8284XSQ-AC:

Advertisement

Quick Links

Avaya
Virtual Services Platform
8000 Series
Quick Install Guide
This poster provides information and instructions to install
and commission a factory-supplied Avaya Virtual Services
Platform 8000 switch. You can download all documents
referenced in this guide at www.avaya.com/support.
1
Before you start
Confirm that you have the following tools and cables:
• Phillips #2 screwdriver
• RJ-45 console port cable
• ESD cable
2
Unpack the equipment and verify
package content
Note: Observe ESD precautions when unpacking.
or
1
3
SLOT
1
5
7
9
2
11
13
4
15
17
1
6
8
19
21
SLOT
3
5
10
12
23
2
7
9
14
16
25
27
11
13
18
29
31
2
4
15
20
22
33
35
6
17
19
24
26
37
8
10
21
23
28
39
12
14
25
30
32
41
16
18
27
29
34
36
VSP
8284XSQ
20
31
33
38
40
22
24
35
37
26
28
39
42
30
32
USB
34
41
36
38
IOIOI
Fan
RPS
PWR
Status
40
42
1. Avaya Virtual Services Platform (VSP) 8000 Series switch
2. Rack-mounting hardware that includes:
a. Rack-mount brackets
b. Screws to attach brackets to the switch
c. Screws to attach the switch to the equipment rack
3. AC power cord or DC power supply wiring assembly
(Note: A power cord is not included with the "A" variants of the
switch.)
4. Documentation that includes this poster, regulatory information,
how to locate software, and how to locate Release Notes.
3
Verify power supply unit (PSU)
specifications
Optionally order a redundant PSU to provide redundancy and
load sharing.
VSP 8200 and VSP 8400 AC power specifications:
VSP 8000
Primary
Redundant PSU
models
PSU
(to be ordered if required)
VSP 8284XSQ-AC
800-W AC
800-W AC power supply
(ships with one AC PSU – order
(order code: EC8005?01-E6)
power supply
code: EC8200?01-E6)
(replacement
order code:
Note: The seventh character (?) of the
VSP 8284XSQ-AC No PC GSA
switch order number must be replaced
(ships with one AC PSU but no
EC8005?01-E6)
with the proper letter to indicate desired
power cord – order code:
product nationalization.
EC8200A01-E6GS)
• "A": No power cord included.
VSP 8284XSQ-AC NA PC GSA
(ships with one AC PSU and a
• "B": Includes European
North American power cord –
"Schuko" power cord common
order code: EC8200E01-E6GS)
in Austria, Belgium, Finland,
France, Germany,
VSP 8404
The Netherlands, Norway,
(ships with one AC PSU but no
and Sweden.
power cord — order code:
EC8400A01-E6)
• "C": Includes power cord
commonly used in the United
VSP 8404
Kingdom and Ireland.
(for government systems)
(ships with one AC PSU but no
• "D": Includes power cord
power cord — order code:
commonly used in Japan.
EC8400A01-E6GS)
• "E": Includes North American
VSP 8404C-AC
power cord.
(ships with one AC PSU
• "F": Includes Australian
– order code: EC8400?02-E6)
power cord.
VSP 8404C-AC NA PC GSA
(ships with one AC PSU
and a North American
power cord – order
code: EC8400E02-E6GS)
VSP 8404C-AC No PC GSA
(for government systems)
(ships with one AC PSU
but no power cord —
order code: EC8400A02-E6GS)
VSP 8200 and VSP 8400 DC power specifications:
VSP 8000
Primary
Redundant PSU
models
PSU
(to be ordered if required)
VSP 8284XSQ-DC
800-W DC
800-W DC power supply
(ships with one DC PSU and a
power supply
(replacement order code:
DC power supply wiring
(replacement order
EC8005001-E6)
assemby – order code:
EC8200001-E6)
code:
EC8005001-E6)
VSP 8404-DC
(ships with one DC PSU and a
DC power supply wiring
assembly — order code:
EC8400001-E6)
VSP 8404C-DC
(ships with one DC PSU and a
DC power supply wiring
assembly — order code:
EC8400002-E6)
4
Install power supply unit
The VSP 8000 Series supports two field-replaceable 800-W
power supplies. One power supply ships with the unit and you
can optionally install a second power supply for redundancy.
If you install a second power supply, the load is shared equally
and neither one acts as a primary power supply.
Use this procedure to install either the primary or redundant
power supply.
Notes:
• Avaya does not support installing a combination of AC-input
and DC-input power supplies in the same chassis.
• There are two power supply slots (PSU1 on top and PSU2 on
the bottom). If you only have one power supply, you can install it
in either PSU1 or PSU2.
• The switch ships with filler panels covering the power supply
slots. If you're not installing a second power supply, you must
leave one of the filler panels in place for proper cooling.
• You can hot swap power supplies while the switch is operational.
One power supply is required for continued
switch operation.
1. Remove the two screws that secure the filler panel to the
chassis. (Save the filler panel for possible future use.)
2. Insert the power supply into the slot.
3. Verify that the power supply is fully seated in the slot (AC PSU
shown). The spring latch should engage and move back to its
original position as shown below:
Notes:
• The chassis design prevents an incorrect installation of a
power supply. If you insert a power supply upside down, it will
not fully insert.
• The spring latch design ensures that you remove the power
cord before removing a power supply from the chassis. If you
don't remove the cord, you cannot move the latch to the left to
release the hooks from the chassis.
4. After you install a power supply, proceed with connecting either
the AC power cord or the DC power supply wiring assembly.
5. Check the LED on the power supply. If it is off, the power supply
is not operating. If it is green, the power supply is operating
normally.
5
Mount the VSP 8000 switch
There are two ways to install an Avaya VSP 8000 switch in an
equipment rack. Refer to one of the following sections:
• Mount the switch using the supplied bracket.
• Mount the switch using the optional slide rack mount kit.
Note: For more details on installing the VSP 8000 Series, see
Avaya VSP 8000 Series Installation (NN47200-300).
Prepare the rack
• Ensure that there is enough rack space to accommodate a
2RU switch (8.8 cm).
• The rack is bolted to the floor and braced if necessary.
• The rack is grounded to the same grounding electrode used
by the power service in the area. The ground path must be
permanent and must not exceed 1 Ohm of resistance from
the rack to the grounding electrode.
Mount the switch using the supplied bracket
Caution: Avaya strongly recommends using the mounting
brackets with a shelf. Using the brackets without a shelf can
cause damage to the rack because of the chassis weight.
When you mount the device in a rack, do not stack units
directly on top of one another.
1. Disconnect the power cord from the switch.
2. Attach a bracket to each side of the switch as illustrated below.
• Use the front set of holes for a 4–post rack installation.
• Use the set of holes near the center of the chassis for a
2–post rack installation.
1
3
5
SLOT
1
7
9
11
13
2
15
4
17
6
1
8
19
3
10
21
5
23
SLOT
2
7
12
25
14
27
9
16
11
18
29
13
20
31
2
15
33
4
22
35
6
17
24
37
8
19
26
21
28
39
10
23
12
30
14
25
32
41
16
27
34
29
36
VSP
8284
18
31
38
XSQ
20
22
33
40
24
35
37
26
39
42
28
30
32
USB
34
41
PWR
36
Consol
Status
38
e
Fan
RPS
40
42
3. Slide the switch onto a shelf in the rack as illustrated.
1
3
SLOT
5
1
7
9
11
13
2
15
4
6
17
1
19
8
21
3
10
23
5
12
SLOT
2
7
14
25
27
9
16
29
11
18
13
20
31
2
15
33
4
22
35
6
17
24
19
26
37
8
21
39
10
28
12
23
30
25
32
14
27
41
16
34
VSP
18
29
36
8284
XSQ
31
38
20
33
40
22
24
35
37
26
39
42
28
30
32
USB
41
34
36
PWR
38
Conso
le
RPS
Status
Fan
40
42
4. Insert and tighten the rack-mount screws.

Advertisement

loading

Summary of Contents for Avaya VSP 8284XSQ-AC

  • Page 1 One power supply ships with the unit and you 3. AC power cord or DC power supply wiring assembly There are two ways to install an Avaya VSP 8000 switch in an can optionally install a second power supply for redundancy.
  • Page 2 EC8011002). For installation information, see the instructions Data terminal ready (DTR) — Switch:1(config)# interface mgmtEthernet mgmt that come with the kit. They are also in Installing the Avaya optional, can swap or link with pin 8 Console port cabling specifications: Switch:1(config-if)# ip address 10.139.43.17/24...

This manual is also suitable for:

Vsp 8404Vsp 8404-dcVsp 8404c-acVsp 8404c-ac na pc gsaVsp 8284xsq-dcVsp 8404c-dc