Turn on Condition:
Important:
The output rise time, from 10 to 90 percent, is 70 ms maximum and monotonic under all defined input
and output conditions.
Efficiency:
Table 4: 800 W AC power specifications
Input Current:
Input Voltage (rms):
Power Consumption:
Thermal Rating:
Inrush Current:
Turn on Condition:
Important:
The output rise time, from 10 to 90 percent, is 50 ms maximum and monotonic under all defined input
and output conditions.
Efficiency:

AC power cord specifications

To connect AC power to the switch, you need an appropriate AC power cord as described in the
following table, also see the following table for plug specifications.
Table 5: International power cord specifications
Country and Plug Specification
Continental Europe:
• CEE7 standard VII male plug
• Harmonized cord (HAR marking on the outside of the cord
jacket to comply with the CENELEC Harmonized
Document HD-21)
United States of America, Canada, and Japan:
• NEMA5-15P male plug
• UL-recognized (UL stamped on cord jacket)
• CSA-certified (CSA label secured to the cord)
January 2015
7254XSQ
5–400 ms delay after application of AC power
85 percent minimum
7254XTQ
9.9–4.79 A
100–240 V, 47–63 Hz
800 W maximum
2730 BTU/Hr maximum
40 A maximum
1 second maximum after application of AC power
70 percent minimum
Installation Job Aid for Avaya Virtual Services Platform 7200 Series
Specifications
• 220 or 230VAC
• 50 Hz
• Single phase
• 100 or 120VAC
• 50–60 Hz
• Single phase
Typical Plug
8