AC power specifications

The following table describes the AC power specifications for the Ethernet Routing Switch 4000
Series.
Model
ERS
4548GT
ERS
4548GT-
PWR
ERS 4550T 3
8
Input
Input
current
current
(amps
(amps
maximum
maximum
at 100-120
at 200-240
VAC)
VAC)
3
1.5
6.5
3.3
1.5
Input
Input
voltage
voltage
(rms, VAC
(rms, VAC
at 50-60
at 50-60
Hz)
Hz)
100-120
200-240
100-120
200-240
100-120
200-240
Power
Thermal
consump-
rating
tion (watts
(Btu/h
max)
maximum)
150
415
470
788
150
240
November 2013