2. Installation and Wiring
2.2.2

Basic wiring

• To control the tension using the LE-30CTN tension controller, perform at least the following wiring.
[1] Connect the AC power supply line of 100 ~ 240 VAC and 50 / 60 Hz between terminals L and N.
When maximum output between PP and PN is readed, the power consumption will be 400 VA.
• Do not connect any 380-VAC power line to the power supply terminals [L] and [N]. The product
may be seriously damaged.
[2] Perform grounding (grounding resistance 100Ω or less) to the grounding terminal and the metal plate.
[3] Connect the tension detector.
[4] If the powder clutch/brake or the hysteresis clutch/brake is used, connect the actuator between
terminals [PP] and [PN]. If the rated current of the powder clutch/brake is 3 A or more, connect the
[TOUT] - [AOC] signal line to the input terminal of the power amplifier that is optimum for the rated
current of the powder clutch/brake, and connect the powder clutch/brake to the output terminal of the
power amplifier.
If the torque controllable servomotor is used, connect the [TOUT] - [AOC] signal line to the torque
command terminal of the servo amplifier.
[5] Connect the start/stop signal line to the [RUN] and [MIC] terminals.
Caution:To perform automatic operation, be sure to turn the [RUN] input signal OFF and
• To use various functions, refer to Sec. 5 and subsequent sections.
Power supply
2.2.3

Wiring of tension detector

[1] While ignoring the loading direction (compression or pulling), connect the cable of the tension
detector as shown in the above figure. The loading direction will be automatically detected.
[2] If only one tension detector is used, short-circuit the unused line between the input terminals ( [GRR]
and [WHR] or between [GRL] and [HWL] ).
14
- - - - - - - - - - - - - - - - - - - - - - - - For conformity to the CE marking, refer to Chapter 13.
ON according to the machine operation status (run or stop).
If this signal is kept at the ON status, restarting the operation of the stopped
machine may apply extremely strong tension to the material, and the material may
fracture.
+10%
AC100 to 240V
-15%
50 / 60Hz
Grounding resistance
100Ω or less
Tension detector
(Right)
Green
White
Red
Black
Green
White
Tension detector
(Left)
RUN / STOP
LE-30CTN
L
N
FG
GRR
WHR
S G
5V
RED
BLK
GRL
WHL
S G
RUN
MC1
MIC
8V
Connect one of the
following actuators.
PP
24 VDC, 3 A or less
Powder clutch / brake
Hysteresis clutch / brake
PN
TOUT
DC0 to 5V
Servo amplifier
Power amplifier
AOC
CAUTION
Do not connect any
380-VAC power line to
the power supply
terminals [L] and [N].
The product may be
seriously damaged.