Monitoring Of Input/Output Signals; Parameter Reset - Mitsubishi LE-30CTN Instruction Manual

Tension controller
Table of Contents

Advertisement

8. Other Functions
8.4

Monitoring of input/output signals

• In the adjustment mode, the conditions of the input signals can be monitored using the LCD display. (The
signal conditions cannot monitored in the operation mode.)
Adjustment/setting item
selection screen
F1
Input/output
monitoring screen
8.5

Parameter reset

• A parameters can be reset to the default factory parameter setting. Carefully use this function because all the
parameter will be reset and the system will be reset to the initial factory setting.
Parameter initialization
F1
completion screen
[1] Turn OFF DIP switch 8, and then turn ON the power to enter the
adjustment mode.
[2] Press the [F1] function key to move to the input/output monitoring
F2
F3
F4
screen.
[3] Using the screen selection keys(6), go to the screen of the item to
monitor.
• Output signal monitoring screen
• Contact input signal monitoring screen
• Analog input signal monitoring screen
screen
[1] Turn ON DIP switch 7, and then turn ON the power to enter the
parameter initialization mode.
[2] Press the [GO] key to initialize the parameter.
F4
Initializes the
parameter
Initialization
Monitor the voltage of the control output [TOUT] and the tension
monitoring or tension set monitoring output [AO1].
Monitor the ON / OFF statuses of the run/stop signal [RUN] and the
general contact signals [M1], [M2], and [M3]. When a signal is in the
ON status, the symbol [ ] will appear.
Monitor the voltages of the general analog input signals [AI1] and
[AI2] signals.
8.4 Monitoring of input/output signals
41