6. Functions of Input/Output Signals
4) Manual output 1/ Manual output 2 selection signal
• Signals to switch the manual output to manual output 1 or manual output 2.
• When these signals are OFF, the manual output 1 will be selected.
• During automatic control, when the manual output signal 1 or 2 is turned ON, the control output will
be fixed to manual output 1 or 2.
• During automatic control, when these signals are turned OFF, automatic control will be started using
the output obtained when turning OFF the signal.
• At starting the machine, by using manual output signal 1 and [RUN] input signal as shown in the
following sequence diagram, the control output can be fixed during acceleration, and change in the
tension can be reduced during acceleration at starting the machine. - - - - - - - - Refer to Sec. 5.1.1.
Control output
Manual setting 1
[RUN] signal
ON
Manual output 1
signal
OFF
Manual output 2
signal
AUTO indicator
LED(11)
Lights
MANUAL indicator
LED(10)
Line speed
Manual setting 1
Control output
[RUN] signal
Manual output 1
signal
AUTO indicator
Flashes
LED(11)
MANUAL indicator
Flashes
LED(10)
Stop timer
Manual
setting 2
ON
OFF
Lights
Goes out
Lights
Goes out
Goes out
Automatic control
Operation speed
Lights
Goes out
Goes out
Goes out
6.1 Contact input signals
Manual setting 1
Flashes
Flashes
Goes out
33