Screen System And Method Of Change Screen; Screen System; Overall Of Screen System - Mitsubishi LE-30CTN Instruction Manual

Tension controller
Table of Contents

Advertisement

3. Screen system and method of change screen

3.
Screen system and method of change screen
3.1

Screen System

3.1.1

Overall of screen system

• The screens shown on the LCD display are shown below. To change screen, use the corresponding
function key (F1 through to F4 keys) or the screen selector keys (
Automatic
mode key
(12)
Manual
mode key
(13)
(Note) When a password setting value is
zero, a password input screen is
not displayed.
Power-on
Operation mode
(When DIP switch 8 = ON)
(When DIP switch 8 = OFF)
Screen displayed
turning off the power
in the operation mode
Tension setting
screen
Manual Setting 1
screen
Manual Setting 2
screen
Taper rate setting
screen
Tension monitoring
screen (Total)
Tension monitoring
screen (Right, Left)
Extension screen
F1
F2
F3
F4
Use the function keys
to go to the desired
screen. The functions
of F1 through F4 keys
depend on the screen.
and
Priority order for screen selection at power-on.
(1) Memory cassette insertion screen
(2) Parameter initialization screen
(3) Adjustment mode screen
When memory cassette
Adjustment mode
(Note)
Memory cassette
Password input screen
operation screen
Adjustment/setting item
selection screen
F1
Select the
F1
F2
F3
F4
operation
type.
[1] Go to the desired
Operation completion
screen using the
corresponding
function key.
• F1 Input/output
After turning off the
monitoring screen
power, remove the
memory cassette.
• F2 Auto zero
Then, turn on the
adjustment screen
power.
• F3 Auto span
adjustment screen
• F4 Menu copy screen
[2] Go to the desired
screen by selecting
the corresponding
item number using
the value setting dial
(16) and then
pressing the
key.
1:Tension setting
2:Manual Setting 1 ,2
3:Taper rate setting
10:Stop timer,
After turning off the power,
Stop gain
turn on DIP switch 8, and
11:Gain 1, gain 2
then turn on the power.
20:Full-scale tension,
Decimal point to
be indicated
21:Tension monitor
40:Proportional gain,
filter time constant
22:Manual zero
41:Additional gain,
adjustment
23:Manual span
adjustment
50:Contact input of
26:Zero tension
detection
51:Analog input of
30:Tension output
filter time constant
52:Extension screen
32:Low excitation
54:Pass word
3.1 Screen System
keys).
Parameter initialization
is inserted
(When DIP switch 7 = ON)
Parameter initialization
screen
F4
F1
Execute
operation.
Initialization
screen
completion screen
After turning off the
power, turn off the DIP
switch 7, and turn on
DIP switch 8. After
that, turn on the power.
Automatic
mode key
(12)
Manual
mode key
(13)
Operation mode screen
integral time
addition dead band
width
MI1, MI2,MI3
AI1,AI2
setting
setting screen
F4
Initializes the
parameter
15

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents