Power Unit configuration error
If there is any violation of system hardware configuration, such as insufficient power supply or
DC-DC converter required by the processors, the power-on sequence will be halted. In this case,
any of the following error messages will be shown on the LCD panel.
Table 14.3
Message level
(1st line)
SCF:alarm
SCF:warning
Power Unit Configuration Error Messages
Message content
(2nd line)
FEP Config. zxy0
Insufficiency of FEP (Front End Bulk Power)
for the system
x : alarmed FEP #, y : installed FEP #
DDC Config. or
Insufficiency or miss configuration of DDC
0X-DDC Config
(DC-DC Converter)
PPU2 Config
Insufficiency or miss configuration of 2.5V
PPU (Power Processing Unit)
PPU3 Config.
Insufficiency or miss configuration of 3.3V PPU
PPU3-io Config
Insufficiency or miss configuration of 3.3V PPU
for IO
PPU5 Config.
Insufficiency or miss configuration of 5.0V PPU
PPU12 Config.
Insufficiency or miss configuration of 12.0V PPU
BE Config
Insufficiency or miss configuration of BE (Back End
Power)
BE(3.3V) Config
Insufficiency or miss configuration of 3.3V BE (Back
End Power)
BE(12V/5V)Config
Insufficiency or miss configuration of 5V BE (Back
End Power)
DDC Config
Extra DDC is installed
PPU3 Config
Extra 3.3V PPU is installed
PPU3-io Config
Extra 3.3V PPU for IO is installed
PPU5 Config
Extra 5.0V PPU is installed
PPU12 Config
Extra 12.0V PPU is installed
BE Config
Extra BE is installed
BE(3.3V) Config
Extra 3.3V BE is installed
BE(12V/5V)Config
Extra 5V BE is installed
14.4 SCF Error Messages
Description
161