Installation specifications
112
Table 9.4
Installation Specifications of Expansion File Unit Type-2
Item
Mass
Power condition
Input voltage
Input frequency
Maximum consumption current
Leakage current (1 for each cable)
Ground resistance
Temperature condition Operating
Not operating
Humidity condition
Operating
Not operating
Vibrations condition
Operating
Idle
Noise
Installation
*1:
If the ambient temperature exceeds 35 degrees Celsius (+95F) during operation, a
warning message is displayed. Take steps to rectify the problem immediately.
*2:
The indicated noise is the mean value of the measurements obtained in an anechoic
chamber with less echoic influence. The actual noise measured at the installation site
may be greater than the indication noise due to surrounding noise and echoes.
Specification
Up to 30kg (approx.70 lb)
Single phase
Single phase
100 to 120 VAC
200 to 240 VAC
(+-10%)
(+-10%)
50/60 Hz (+2 to -4%)
3.0 A
1.5 A
1.2 mA or less
2.7 mA or less
100ohm or less ( class C installation standard)
5 to 35 degrees Celsius (+41 to +95 F) (*1)
0 to 50 degrees Celsius (+32 to +122F)
20 to 80%RH (no condensation)
8 to 80% RH (no condensation)
0.2 G
0.4 G
50 db (A) (*2)
Rack mount type (3 pitches)