3.7.13 Touch Trigger Probes

Any of the following touch trigger probes for workpiece measurement can be connected.
TS 220
Touch trigger probe with cable connection: for digitizing, workpiece setup and
workpiece measurement during machining
TS 630
Touch trigger probe with infrared transmission: for workpiece setup and workpiece
measurement during machining
X12 Touch Probe Input for Workpiece Measurement
Logic unit
D-sub terminal
Assignment
(female) 15-pin
1
0 V
3
Ready
4
Start
5
+15 V ± 10% (maximum 100mA)
6
+ 5 V ± 5% (maximum 100mA)
7
Battery warning
8
0 V (U
9
Trigger signal
10
Trigger signal
2, 11 to 15
Do not use
Housing
External shield
Stylus at rest means logic level High