HEIDENHAIN TNC 370 D Technical Information page 56

Table of Contents

Advertisement

Machine
Function and input
parameter
MP60
PLC-auxiliary axis
Input:
Bit
Axis
Assignment of the position measuring
MP110.0-3
system inputs for the axes
Input:
0 = no position measuring system
1 = position measuring system input X1
2 = position measuring system input X2
3 = position measuring system input X3
4 = position measuring system input X4
6 = position measuring system input X6
MP111
Assignment of the position measuring
system input for the spindle
Input:
0 = no position measuring system
1 = position measuring system input X1
2 = position measuring system input X2
3 = position measuring system input X3
4 = position measuring system input X4
6 = position measuring system input X6
MP112.0-3
Assignment of the rpm measuring system
inputs for the axes
Input:
0 = no rpm measuring system input (analog
axis)
15 = rpm measuring system input X15
16 = rpm measuring system input X16
17 = rpm measuring system input X17
18 = rpm measuring system input X18
19 = rpm measuring system input X19
MP113
Assignment of the rpm measuring system
inputs for the spindle
Input:
0 = no rpm measuring system input (analog
axis)
15 = rpm measuring system input X15
16 = rpm measuring system input X16
17 = rpm measuring system input X17
18 = rpm measuring system input X18
19 = rpm measuring system input X19
July 02
%xxxx
0 to 3
0 = not active
X to 4
1 = active
0 to 6
0 to 6
15 to 19
15 to 19
Machine Parameters
Change via Reaction
Reset
Reset
Reset
Reset
Reset
TNC 370 D
4–53