The following wiring plan is suggested for shielding in the terminal box :
LE
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
IV
X
Y
Z
S
SERVO
Connection
terminal
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
3–16
TNC 370 D
Insulated against housing
Leads are provided
with en sleeves.
Cable screens are led onto 0.14 mm
insulated strands via crimp eyelets.
Assignment
Nominal value output
Nominal value output 0 V
Nominal value output
Nominal value output 0 V
Nominal value output
Nominal value output 0 V
Nominal value output
Nominal value output 0 V
Not used
Not used
Nominal value output
Nominal value output 0 V
Shield connection
Shield connection
Shield connection
Shield connection
Mounting and Electrical Installation
Insulated against housing
2
Leads are provided with end sleeves
Cable shields are led onto 0.14 mm² insulated
wires via crimp eyelets.
X axis
X axis
Y axis
Y axis
Z axis
Z axis
IV axis
IV axis
S axis
S axis