X48 Analog Input (PLC) at the LE
D-sub terminal
Assignment
(female) 25-pin
1
I
+ Constant current for Pt 100
1
2
I
– Constant current for Pt 100
1
3
U
1
4
U
1
5
I
+ Constant current for Pt 100
2
6
I
– Constant current for Pt 100
2
7
U
2
8
U
2
9
Do not use
10
Do not use
11
Do not use
12
Do not use
13
Do not use
14
Analog input 1 –10 V to +10 V
15
Analog input 1 0 V (reference potential)
16
Analog input 2 –10 V to +10 V
17
Analog input 2 0 V (reference potential)
18
Analog input 3 –10 V to +10 V
19
Analog input 3 0 V (reference potential)
20 to 25
Do not use
Housing
External shield
The correct polarity of analog inputs is essential.
X15, X16, X17, X18 Analog inputs on the PL 410 B
Terminal
Assignment
1
–10 V to +10 V
2
0 V (reference potential)
3
Shield
3–38
TNC 370 D
+ Measuring input for Pt 100
– Measuring input for Pt 100
+ Measuring input for Pt 100
– Measuring input for Pt 100