HEIDENHAIN TNC 370 D Technical Information page 65

Table of Contents

Advertisement

Machine
Function and input
parameter
MP3240.1
Minimum nominal value voltage
Input:
MP3240.2
Jog voltage for gear changing
(M4009/M4010)
Input:
MP3310
Limits for spindle override
Input:
MP3310.0
Upper limit
MP3310.1
Lower limit
MP3411
Ramp gradient of the spindle at M03 and
M04
Input: 0.000 to 1.999 [V/ms]
MP3411.0-7
Gear range: 1 to 8
Multiplier for MP3411.x
MP3412
Input:
For M05
MP3412.0
For spindle orientation
MP3412.1
For tapping
MP3410.2
For rigid tapping
MP3410.3
Transient response of the spindle
MP3415
(functions like MP1520)
Input:
for M03, M04 and M05
MP3415.0
for spindle orientation
MP3415.1
for tapping
MP3415.2
for rigid tapping
MP3415.3
MP3420
Positioning window for the spindle
Input:
Deviation of the reference mark from the
MP3430
desired position (spindle preset)
Input:
4–62
TNC 370 D
0 to 9.999 [V]
0 to 9.999 [V]
0 to 150 [%]
0.000 to 1.999
0 to 1000 [ms]
0 to 360.000 [°]
0 to 360.000 [°]
Machine Parameters