Table of Contents

Advertisement

4.12 Tapping

Machine
Function and input
parameter
MP7110.0
Minimum for feed-rate override during
tapping
Input:
MP7110.1
Maximum for feed-rate override during
tapping
Input:
MP7120.0
Dwell time for reversal of spindle rotation
direction
Input:
MP7120.1
Advanced switching time of the spindle for
tapping with coded output of the spindle
speed
Input:
MP7120.2
Spindle slow-down time after reaching the
total hole depth
Input:
MP7130
Approach behavior of the spindle for rigid
tapping
Input:
MP7150
Positioning window of the tool axis for rigid
tapping
Input:
MP7160
Spindle orientation with Cycle 17
Input:
0= spindle orientation before execution of
Cycle 17
1= no spindle orientation before execution
of Cycle 17
4–70
TNC 370 D
0 to 150 [%]
0 to 150 [%]
0 to 65.535 [s]
0 to 65.535 [s]
0 to 65.535 [s]
0.01 to 10.000 [°/min]
0.001 to 2.000 [mm]
Machine Parameters
Change via Reaction
PLC
RUN
PLC
RUN
PLC
RUN
PLC
RUN
PLC
RUN
PLC
PLC
CN
PLC
RUN
July 02