Installing the Avaya Virtual Services Platform 7200 Series
Figure 2: VSP 7200 — Rear view
1. Console port
2. Management port — The LEDs are on the bottom of the port. For more information, see
LEDs
on page 38.

Electrostatic discharge

This section provides information and procedures to prevent electrostatic discharge during
installation.
Preventing electrostatic discharge damage
Electrostatic discharge (ESD) is a discharge of stored static electricity that can damage equipment
and impair electrical circuitry. Electrostatic voltages can result from friction including, pulling cabling
through conduits, walking across carpeted areas, and building static charge in clothing. When you
improperly handle electronic components, ESD damage occurs and can result in complete or
intermittent failures. While networking equipment is commonly designed and tested to withstand
common mode ESD events, voltage can sometimes discharge to some connector pins, which can
potentially damage the networking equipment.
Caution:
To protect the switch against ESD damage, take the following measures before you connect
data cables to the device:
• Always use antistatic wrist straps. Make sure you adjust the strap to provide good skin
contact.
• Ensure that you properly ground work surfaces and equipment racks for protection against
electrostatic discharge. You must connect the common point to the building ground wire. In
a properly wired building, the nearest reliable ground is typically at the electrical outlet.