CPU BOARD DIP SWITCHES
6-7. Operation ON/OFF Log
Log data for date and time when the [RUN] SW of SRX-101A is turned off or on will be displayed.
Total count of operation ON/OFF of the SRX-101A is 8,192. Those exceeding the maximum count
for operation ON/OFF will overwrite the oldest log in order.
1. DIP Switch setting
2. Operation Method
1) Set the DIP switches as shown above, and turn on the Power breaker.
· The latest status of the SRX-101A (Pon = Power ON, Pof = Power OFF) will be displayed by
the 7seg.LED.
2) Every time when the [RUN] SW is pressed ;
· Operation ON or OFF data just before the latest → Operation ON or OFF data two times before the
latest → Operation ON or OFF data three times before the latest...Will be displayed in order.
3) Pressing the [Repl.] SW will return to the latest operation ON or OFF data.
3. Details of 7seg.LED display
operation
Push the [Repl.] SW
Push the [RUN] SW
Push the [RUN] SW
Push the [RUN] SW
Push the [RUN] SW
Push the [RUN] SW
Push the [RUN] SW
Push the [RUN] SW
Push the [RUN] SW
66
SERVICE MANUAL
DS1-1
DS2
7seg. display
Pon
Displays the status
or
(operation ON or OFF)
PoF
↓
'YY
Displays the year (YY).
↓
Displays the month (M) & date (DD). Information for the latest operation
M.DD
"A" for October, "B" for November,
"C" for December.
↓
HHh
Displays the hour (HH).
↓
MM-
Displays the minute (MM).
↓
-SS
Displays the second (SS).
↓
Pon
Displays the status
or
(operation ON or OFF)
PoF
↓
Continues to display as long as the data is available.
↓
End
End of display
Poo
Displayed when there is no log data available.
ON
[4]
contents
ON or OFF, and its time and
date (YY/MM/DD).
Information for the operation ON
or OFF just before the latest, and
its time and date (YY/MM/DD).