13.Screw in the two diagonally arranged threaded bars and slide the cover onto these bars.
14.Fix the two free screw connections and tighten by hand.
15.Remove the threaded bars and screw in the two other screws.
16.Tighten all screws (4 x M10, tightening torque 40 Nm).
See also
Connecting cables with cable lugs (Page 80)
Connecting cables without cable lugs (Page 80)
Bringing cables into the terminal box 1XB... with cable gland (Page 78)
6.2.8

Mounting/removing the terminal box

When removing or installing the terminal box cover, secure it using diagonally arranged M10
threaded bars to prevent it falling.
Removing the terminal box
1. Release two diagonally opposing screws at the terminal box cover and replace them by
2. Release the two other screws.
3. Carefully pull the terminal box cover over the threaded bars.
Mounting the terminal box
1. Screw in the two threaded bars diagonally at the lower section of the terminal box.
2. Slide the terminal box cover over the threaded bars onto the lower section of the terminal
3. Screw the screws into the free holes and tighten by hand.
4. Release the threaded bars.
5. Tighten all four M10 screws, tightening torque 40 Nm.
SIMOTICS FD 1LL1
Operating Instructions 04/2016
Take care not to damage the seal.
threaded bars.
box.
Electrical connection
6.2 Terminal box
73