8.5 Stoppages
8.5.1

Avoidance of condensation or formation of condensation within the machine

● If the controller does not do this automatically, switch on any anti-condensation heating
● Do not switch on the anti-condensation heating for at least two hours after the motor has
8.5.2

Avoidance of damage to roller bearings during stoppages

Extended stoppages at the identical or almost identical resting position of the roller bearings
can lead to damage such as brinelling or formation of corrosion.
● During stoppages, regularly start the machine up for a brief period once a month, or at least
● During re-commissioning, refer to the information in the "Commissioning" section.
See also
Start-up (Page 91)
8.5.3

Measurement of the insulation resistance after an extended stoppage

Measuring the insulation resistance and polarization index (PI) provides information on the
condition of the machine. It is therefore important to check the insulation resistance and the
polarization index at the following times:
● Before starting up a machine for the first time
● After an extended period in storage or downtime
● Within the scope of maintenance work
The following information is provided regarding the state of the winding insulation:
● Is the winding head insulation conductively contaminated?
● Has the winding insulation absorbed moisture?
As such, you can determine whether the machine needs commissioning or any necessary
measures such as cleaning and/or drying the winding:
● Can the machine be put into operation?
● Must the windings be cleaned or dried?
Detailed information on testing and the limit values can be found here:
108
during stoppages. This will avoid the formation of condensation.
been switched off. This prevents damage to the winding insulation.
turn the rotor over several times.
If you have uncoupled the machine from the driven machine and secured the rotor with a
rotor shipping brace, then remove this before turning the rotor over or starting the machine
up.
Make sure that the resting position of the roller bearings after the rotor has been turned
over is different from what it previously had been. Use the fitted key or the coupling halves
as reference markers.