Prepare the mating faces (IM B3)

● Ensure that the foundation faces are flat and free of contaminations.
● Check the dimensions of the mounting-foot holes.
See also
Removing anti-corrosion protection (Page 51)
Requirements for safe lifting and transporting (Page 34)
Service and Support (Page 155)
5.1.5

Prepare the mating face for a flange connection

● Clean the flange before installation, and make sure that the flange face is flat and free of
● Check the geometry of the flange.
See also
Removing anti-corrosion protection (Page 51)
Requirements for safe lifting and transporting (Page 34)
5.1.6

Prepare the mating face for wall mounting

● Ensure that the wall surface is flat and free of contaminations.
● Check the dimensions of the mounting-foot holes.
● Support the machine from below, e.g. using a wall bracket or by bolting it.
SIMOTICS FD 1LL1
Operating Instructions 04/2016
Note
Shims
To establish a defined mounting surface, you can order shims (option L31) from our Service
Center. In this way you avoid vibration problems that would otherwise result in bearing
damage.