NOTICE
Improper handling
Mounting parts such as temperature sensors or speed sensors are attached to the machine
and could be ripped off or destroyed as a result of improper handling. This could lead to
machine malfunctions, extending even to total loss of the machine.
● Where necessary, use suitable steps when performing installation work on the machine.
● Do not stand on cables or attachments during installation. Do not use attachments as
5.3.2

Selecting fixing screws

● Unless specified otherwise, use mounting bolts with at least strength class 8.8 to ISO 898‑1.
● Take into account the maximum forces occurring in the case of a fault such as short circuit
See also
Technical data and drawings (Page 157)
5.3.3

Preconditions for smooth, vibration-free operation

Preconditions for smooth, vibration-free operation:
● Stable foundation design
● Precise alignment of the machine
● Correct balancing of parts to be fitted to the shaft end.
● Maintaining the vibration velocity according to ISO 10816‑3
SIMOTICS FD 1LL1
Operating Instructions 04/2016
steps.
In this way you guarantee that the machine is securely mounted and the forces can be
transferred through the torque.
or system transfers in phase opposition.
– When selecting the bolts
– When designing the foundation
Assembly
5.3 Installing the machine