Connect the adapter to the Textool
starterkit using flat cable. Start the GALEP5 programmer software and use 'Load' command
to load a bin or hex file. Select tab 'Devices' and browse to the correct device, e.g. MCU
Fujitsu
MB91F467D. Choose SYNC for serial synchronous programming. In the
information window below the correct programming adapter is listed. Use 'Select Device!'
button to accept current selection.
Use the functions now enabled on the bottom of the window to select action:
•
Program: write loaded mhx/bin-file to MCU
•
Verify: compare loaded file to Flash contents
•
Blank: do a blank check
•
Read: read-out Flash content
•
Erase: perform a chip erase
After selecting a operation, tab 'Action' is automatically activated. Press 'Start' button to start
operation.
For further information on available settings in software and jumper settings on starterkits
have a look at 'Options"
MCU-AN-300012-E-V13
Serial Asynchronous Flash Programming
Chapter 4 GALEP-Programmer
Figure 30: Serial Synchronous Programming
TM
–socket (pins 5-44) and connect the adapter to the
'MB91F467D Options" (or other MCU type) and 'Device Help'.
- 32 -
© Fujitsu Microelectronics Europe GmbH