Enhanced Communicator Features

[67] Telephone Number 1
(1) Opening After Alarm (Cancel Code) -
When enabled, all users that are not se-
lected to report on Opening/Closing [39] will
report an Opening only when opening after
an alarm has occurred.
(2) Conditional Closing Telephone 1 -
When enabled, all users that are not se-
lected to report an Opening/Closing ([39],
[59]) will report a Closing only when zones
have been bypassed.
The Zone Trouble
Code [62-2] is used to report zones that
have been bypassed at the time of the clos-
ing report.
(3) Reserved
(4) Reserved
[68] Telephone Number 3
(1) Opening after Alarm (Cancel Code) -
see [67-1].
(2) Conditional Closing Telco 3 - see
[67-1].
(3) Reserved
(4) Reserved

Wireless

Up to two receivers can be wired to the
GEM-P800. Each wireless transmitter can
be mapped to a zone. Only 1 wireless de-
vice is permitted per zone, however, the use
of both hardwired and wireless on a zone is
permitted.
To Map a transmitter to a zone:
1. Enter the Programming Block Number
that the transmitter is to be mapped to.
2. Enter the 7-digit RF ID number directly,
just as it is shown on the device label.
After the 7th digit is entered the keypad
will beep.
A transmitter will send a transmission every
time it is tripped. The transmitter also sends
a supervisory transmission about once
every hour. If the receiver does not receive
a signal from a transmitter in the time pro-
grammed in Wireless Supervisory Timer, a
system trouble 'RF Supervisory Failure' will
be indicated at the keypad.
Program Wireless Supervisory Timer [16] to
change the supervisory time from the default
of 12 hours.
The Signal strength of a transmitter can be
checked at the keypad (see
Fault Find Mode) or saved to the LOG (see
Signal Strength Logging Mode - pg. 11).
[71-78] Wireless Transmitters
Enter the RF ID# and the point number that
is to be mapped to the zone.
Programming Example
Map point 1 of a window door transmitter
with an RF ID# of 0012B0:0 to Zone 3.
1. Enter Dealer Mode.
2. Enter
C
3. Enter
012G200
4. Enter
1
Note: If the RF ID# in step 3 is not entered
correctly the keypad will emit a 1 second
tone indicating incorrect entry.
steps 2 - 4 above.
[81] - [84] Wireless Keyfobs
The GEM-KF is a hand held wireless trans-
mitter capable of Arming and Disarming the
control panel and/or activating 2 Auxiliary
Functions.
tions, press and hold the
1.5 seconds (see WI752 for more informa-
tion).
Enter the RF ID# and AUX 1 and AUX 2
options for each Keyfob.
AUX 1 & AUX 2
A7
Programming Options:
1 Panic
Program a 1 in the AUX 1 and/or AUX 2
option to initiate a panic alarm when the
or
buttons on the Keyfob are pressed.
N
Additional programming required:
Keypad Panic (
Panic Report to Telco 1[36-2] and/or Telco 3
[56-3].
(
beeps)
(beeps)
73
(beeps)
Repeat
To activate the auxiliary func-
or
key for
M
N
M
) [20-3]
9G
19