WI850D GEM-P800 Installation Instructions
Audible Panic (Optional) [21-1]
2 AUX
Program a 2 in the AUX 1 and/or AUX 2
option to initiate a AUX alarm when the
or
buttons on the Keyfob are pressed.
N
Additional programming required:
Keypad AUX (
8G
AUX Report to Telco 1[36-2] and/or Telco 3
[56-2].
3 Bell ON
Program a 3 in the AUX 1 and/or AUX 2
option to turn the Bell ON when the
buttons on the Keyfob are pressed.
N
Press the
button to turn the Bell OFF.
L
4 PGM
Program a 4 in the AUX 1 and/or AUX 2
option to activate the PGM Output when the
or
buttons on the Keyfob are
M
N
pressed. Press the
L
PGM Output OFF.
5 Instant
Program a 5 in the AUX 1 and/or AUX 2
option to activate Instant Mode when the
or
buttons on the Keyfob are
M
N
pressed.
6 Access on PGM
Program a 6 in the AUX 1 and/or AUX 2
20
option to activate the PGM Output for 5 sec-
onds when the
Keyfob are pressed.
Addition programming required:
M
Enable Access Output [23-2]
7 Full Set System
Program a 7 in the AUX 1 and/or AUX 2
) [20-2]
option to Fully Set the System when the
and the
are pressed, or when the
tons are pressed when the system is armed
with Exit/Entry Follower Zones or Home/
Away with Delay Zones that have been by-
or
M
passed.
8 Interior
Program an 8 in the AUX 1 and/or AUX 2
option to Bypass Exit/Entry Follower Zones
or Home/Away with Delay Zones when the
M
pressed (only if the system is programmed
button to turn the
exclusively for Home/Away with Delay
Zones).
[85] - [88] Wireless Smoke Detectors
Enter the RF ID# of the smoke detector.
A wireless smoke detector sends a supervi-
sory transmission about once every hour. If
the receiver does not receive a signal from a
transmitter in the time programmed in Wire-
or
buttons on the
M
N
or
buttons on the Keyfob
M
N
or
M
N
or
buttons on the Keyfob are
N
less Smoke Supervisory Timer, a system
trouble 'RF Smoke Supervisory Failure' will
be indicated on the keypad.
Program Wireless Smoke Supervisory Timer
[17] to change the time from the default time
of 8 hours. Refer to Household Fire [96-3].
Note:
Mark Smoke Detectors (Smoke 1
through Smoke 4) in order to identify them in
K
the event of a supervisory or battery failure.
If Household Fire [96-4] is selected, Wire-
but-
less Smoke Supervisory Time is fixed at 4
hours.

Downloading

[90] Callback Telephone Number
Program
the
phone
downloading computer to be dialed by the
panel during a high security download.
[91] Ring Count
Program the number of rings before the
panel will pickup.
(Downloading Features) must also be se-
lected.
[92] Downloading Features
(1) Ring Method - Enable the ring method
of downloading. The panel will pick-up on
the number of rings programmed in Ring
number
of
the
Ring Method [92-1]