8.1 Light Source Section
8.1.2 CLE23 Circuit Board Replacement
Removal
1. Remove the light source unit
2. Disconnect the four connectors from the CLE23
circuit board.
3. Remove the six screws and then the CLE23
circuit board.
Installation
Installation is essentially in the reverse order of
removal.
After installation, perform the following adjustment.
1) Download the program from the HD of the
main control unit to the CLE23 circuit board
(See Subsection 8.2.17)
2) In Menu 0350 "Scanner Parameter Check/
Update", click the [Reading] button for "CLE23
CB" to download the parameter from the HD of
the main control unit to the EEPROM on the
CLE23 circuit board
8.1.3 135/120 Diffusion Box Sensor (D301/D302) Replacement
Removal
1. Remove the light source unit
2. Disconnect the CLE5 connector from the CLE23
circuit board.
3. Open the two harness clamps.
Distributed by minilablaser.com
.
(See Subsection 8.1.1)
.
.
(See Subsection 5.4.16)
.
(See Subsection 8.1.1)
CLE2 Connector
CLE23 Circuit Board
Harness Clamps
8-4
CLE4 Connector
CLE23 Circuit Board
CLE5
Connector
CLE3 Connector
Z2160
Screws (6)
Z2161
CLE5 Connector
Z2163