7.4 NC100AY Body Section
14. Disconnect the harness from the CYA6 connector.
Installation
Installation is essentially in the reverse order of
removal.
NOTE: • Insert the flexible cable into the connector so that
its blue contact area disappears.
• Tighten the two screws while pressing the guide
rail toward the left side.
• Align the hook of the harness cover with the pin on
the body and install the cover being careful not to
pinch the harnesses.
• Perform machine data reading by following the
steps below.
Distributed by minilablaser.com
CYA6 Connector
Harness Cover
7-77
Harness
Guide Rail
Hook
Z2250
7
Z2251
Pin
Z2480