16.1 Replenisher Cartridge Section
16.1.1 Replenisher Box Door Open/Close Detecting Interlock Switch
(D724) Replacement
Removal
1. Remove the processor front cover
.
(See Subsection 15.1.1)
2. Loosen the screw, remove the other one and then
the switch bracket.
3. Remove the screw and then the connector cover.
4. Disconnect the connector from the switch.
5. Remove the spring and E-ring then the switch.
Installation
Installation is essentially in the reverse order of removal.
16.1.2 Replenisher Cartridge Setting Sensor (D721) Replacement
Removal
1. Remove the processor front cover
.
(See Subsection 15.1.1)
2. Remove the screw and then the sensor bracket.
Distributed by minilablaser.com
Screw
Screw Connector Cover
E-ring
Switch
16-3
Screw (Loosen)
Switch Bracket
Connector
Spring
Sensor Bracket
Screw
LII676
LII677
16