Shutter Open/Close Sensor (D674) Replacement - FujiFilm SP-3000 Service Manual

Digital minilab
Hide thumbs Also See for SP-3000:
Table of Contents

Advertisement

12.2 Laser Optical Unit

12.2.5 Shutter Open/Close Sensor (D674) Replacement

Removal
1. Remove the laser optical unit
2. Remove the five screws and then the shutter
section lower bracket.
3. Disconnect the connector from the sensor.
4. Release the locking tabs then remove the sensor.
Installation
Installation is essentially in the reverse order of removal.
12.2.6 Exposure Point Thermometer (TS650) Replacement
Removal
1. Remove the laser optical unit
2. Remove the two screws and then the cover.
Distributed by minilablaser.com
.
(See Subsection 12.2.3)
.
(See Subsection 12.2.3)
12-15
Screws (5)
Shutter Section Lower Bracket
Connector
Locking Tabs
Cover
Screws (2)
LII462
Sensor (D674)
12
LII464
LII465