12.3 Sub-scanning Unit
7. Remove the sub-scanning unit.
Reinstallation
Reinstallation is essentially in the reverse order of
removal.
NOTE: • Insert the two locating jigs into the holes in the
frame. Position the frame so that the locating jigs
fall into the locating holes smoothly and tighten the
eight sub-scanning unit mounting screws. Make
sure the jigs can be removed easily.
• When the sub-scanning unit has been replaced,
perform the following adjustments.
1)Menu 0558 "Sensor Calibration (Initial)"
(See Subsection
5.6.25).
2)Menu 0554 "Image Position Initial Setting"
(See Subsection
5.6.22).

12.3.2 Frame Removal/Reinstallation

Removal
1. Remove the sub-scanning unit
2. Open the five harness clamps.
3. Remove the four screws and then the frame.
Reinstallation
Reinstallation is essentially in the reverse order of
removal.
Distributed by minilablaser.com
.
(See Subsection 12.3.1)
12-18
Unit
Screws (8)
Jig
Screws (4)
Frame
LII427
LII453
Clamps (5)
LII428