7.11.1 Preparing for cleaning

NOTICE
Prerequisite GN containers, baking sheets and grates removed from the cooking

7.11.2 Selecting the cleaning level

INFORMATION
INFORMATION
Tip
Prerequisite Unit is on
Risk of property damage from improper cleaning
• Do not clean the unit with a high-pressure cleaner or water jet.
chamber
1. Remove any food remains from the cooking chamber.
The drainage sieve is not obstructed.
2. Leave only the hang-in frame in the cooking chamber in tabletop
units and the tray trolley in the cooking zone in pedestal units.
3. Close the cooking chamber door.
If the water pressure drops during cleaning, the cleaning program switches to
a standby mode. Once the water pressure is restored, the cleaning program
resumes automatically.
Despite different cleaning durations, all cleaning steps require the same
amount of water.
For automatic cleaning overnight, we recommend the cleaning levels "normal"
or "extra". This ensures adequate drying.
Main menu is displayed
1. Tap Unit function.
2. Tap the WaveClean symbol.
3. Selecting the cleaning level.
The Operating instruction window is displayed.
4. Tap the Confirm button.
The Select cleaning level window is displayed.
5. Tap the "Start Stopp" button.
If necessary, the cooking chamber is cooled down until the
cleaning temperature of 60 °C (140 °F) is reached.