Cyclic Communication - Siemens SINAMICS G150 Operating Instructions Manual

Converter cabinet units 1750 kw 2700 kw
Hide thumbs Also See for SINAMICS G150:
Table of Contents

Advertisement

Operation
6.7 Communication according to PROFIdrive
Telegram
(p0922 = x)
106
Speed setpoint, 32 bit with 2 position encoders, torque reduction and
DSC
110
Basic positioner with MDI, override and XIST_A
111
Basic positioner in the MDI mode
116
Speed setpoint, 32 bit with 2 position encoders, torque reduction and
DSC, plus actual load,
torque, power and current values
118
Speed setpoint, 32 bit with 2 external position encoders, torque re-
duction and DSC, as well as actual load, torque, power and current
values
125
DSC with torque feedforward control, 1 position encoder (encoder 1)
126
DSC with torque feedforward control, 2 position encoders (encoder 1
and encoder 2)
136
136 DSC with torque feedforward control, 2 position encoders (en-
coder 1 and encoder 2), 4 trace signals
138
DSC with torque precontrol, 2 external position encoders (encoder 2
and encoder 3), 4 trace signals
139
Closed-loop speed/position control with DSC and torque feedforward
control, 1 position encoder, clamping status, supplementary actual
values
166
Manufacturer-specific telegram for hydraulic axis (HLA) with 2 en-
coder channels and HLA additional signals
220
Speed setpoint 32 bit, metal industry
352
Speed setpoint, 16 bit, PCS7
370
Infeed
371
Infeed, metal industry
390
Control Unit with digital inputs/outputs
391
Control Unit with digital inputs/outputs and 2 probes
392
Control Unit with digital inputs/outputs and 6 probes
393
Control Unit with digital inputs/outputs and 8 probes
394
Control Unit with digital inputs/outputs
395
Control Unit with digital inputs/outputs and 16 probes
396
Telegram for the transfer of DU-global status data (DO CU), for the
control of the digital I/O on SOC-CUs, as well as for 8 CU probe
channels and 8 CU cam controllers
999
Free telegrams
6.7.3

Cyclic communication

Cyclic communication is used to exchange time-critical process data (e.g. setpoints and
actual values).
318
Description
Class 1
Class 3
x
x
x
x
x
x
x
x
x
x
x
x
x
Converter cabinet units
Operating Instructions, 07/2016, A5E03347396A
Class 4
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents