Siemens SINAMICS G130 Operating Instructions Manual page 292

Converter built-in units 75 kw-800 kw
Hide thumbs Also See for SINAMICS G130:
Table of Contents

Advertisement

Operation
6.10 Communication via EtherNet/IP
Table 6- 40
No.
2
3
6
7
8
9
10
11
12
13
14
15
19
TCP/IP Interface Object, Instance Number: F5 hex
Supported services
Class
Table 6- 41
No.
1
2
3
292
Instance Attribute
Service
Type
Name
get, set
UINT16
Commisioning
state
get
INT16
Motor Type
get, set
REAL
Rated Current
get, set
REAL
Rated Voltage
get, set
REAL
Rated Power
get, set
REAL
Rated Frequency
get, set
REAL
Rated Tempera-
ture
get, set
REAL
Max Speed
get, set
UINT16
Pole pair number
get, set
REAL
Torque Constant
get, set
REAL
Inertia
get, set
REAL
Base Speed
get, set
REAL
Cos Phi
• Get Attribute all
• Get Attribute single
Class Attribute
Service
Type
get
UINT16
get
UINT16
get
UINT16
Value/explanation
p0010: commissioning parameter filter
p0300: motor type
p0305: rated motor current
p0304: rated motor voltage
p0307: rated motor power
p0310: rated motor frequency
p0605: Mot_temp_mod 1/2 / sensor threshold and
temperature value
p0322: maximum motor speed
p0314: motor pole pair number
p0316: motor torque constant
p0341: motor moment of inertia
p0311: rated motor speed
p0308: rated motor power factor
Instance
Name
Revision
Max Instance
Num of Instances
Operating Instructions, 07/2016, A5E00331449A
• Get Attribute all
• Get Attribute single
• Set Attribute single
Inverter chassis units

Advertisement

Table of Contents
loading

Table of Contents