Vertical terminations

Three (3) 90° Elbows (Rigid Pipe 4" x 6 - 5/8")
One 90
elbow = Two 45
o
Option
V
H + H1 V + V1
A)
0' Min.
2' Max. 2' Min.
B)
1' Min.
2' Max. 3' Min.
C)
2' Min.
3' Max. 4' Min.
D)
3' Min.
4' Max. 6' Min.
E)
4' Min.
5' Max. 7' Min.
F)
5' Min.
6' Max. 8' Min.
G)
6' Min.
7' Max.
H)
7' Min.
8' Max. 10' Min.
No Vent Restrictor Installed
*Required when using rigid venting
Lengths do not include elbow indicated.
elbows.
o
With these options, max.
total pipe length is 30 feet
with min. of 10 feet total
vertical and max. 8 feet
total horizontal.
Please note min. 1 foot
between 90
elbows is
o
9' Min.
required.