Vertical Terminations -

The minimum components required for a basic vertical termination are:
1
Vertical Termination Cap
1
Rigid Pipe Adaptor (770-994)
1
Ceiling Firestop
1
Flashing
1
Storm Collar
1
Length of pipes to suit wall thickness & vent run
(see chart)
Galvanized pipe is desirable above the roofline due to its higher corrosion
resistance. Continue to add pipe sections through the flashing until the
height of the vent cap meets the minimum height requirements specified
in table below or local codes. Note that for steep roof pitches, the
vertical height must be increased. A poor draft, or down drafting
can result from high wind conditions near big trees or adjoining
roof lines, in these cases, increasing the vent height may solve the
problem.
Roof Pitch
Minimum Vent Height
Feet
flat to 7/12
2
over 7/12 to 8/12
2
over 8/12 to 9/12
2
over 9/12 to 10/12
2.5
over 10/12 to 11/12
3.25
over 11/12 to 12/12
4
over 12/12 to 14/12
5
over 14/12 to 16/12
6
over 16/12 to 18/12
7
over 18/12 to 20/12
7.5
over 20/12 to 21/12
8
WARNING:
Do not combine venting components from different venting systems.
However use of the the AstroCap
This product has been evaluated by Intertek for using a Rigid Pipe Adaptor in conjunction with
Duravent Direct-Vent, Selkirk Direct-Temp, Ameri Vent Direct Venting, ICC Excel Direct, Olympia
Ventis DV, and Security Secure Vent systems. Use of these systems with the Rigid Pipe adaptor is
deemed acceptable and does not affect the Intertek WHI listing of components.
The FPI AstroCap
and FPI Riser Vent terminal are certified for installations using FPI venting systems as well as Simpson Dura-Vent
TM
Metal Products Ameri Vent Direct Vent, Security Secure Vent
of FPI Fireplace Products International Ltd. Dura-Vent® and Direct Vent are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc.
" (Non Power Vent)
Rigid Pipe 5" x 8
Meters
0.61
0.61
0.61
0.76
0.99
1.22
1.52
1.83
2.13
2.29
2.44
and FPI Riser is acceptable with all systems.
TM
, ICC Excel,
®
Storm Collar
Flashing
Ceiling Firestop
Olympia Ventis DV,
Selkirk Direct-Temp. AstroCap
City Series CV50E Direct Vent Gas Fireplace |
Vertical Terminal
Pipe Length
Rigid Pipe Adapter
*Unit is not exactly as shown.
When using Rigid Vent other than
Simpson Dura-Vent, 3 screws must be
used to secure rigid pipe to adaptor.
Direct Vent, American
®
is a proprietary trademark
TM