Venting Arrangements With Co-Linear Flex System - Regency G800EC Owners & Installation Manual

Hide thumbs Also See for G800EC:
Table of Contents

Advertisement

installation
Venting arrangements
with Co-linear Flex System
THE APPLIANCE MUST NOT BE
CONNECTED TO A CHIMNEY FLUE
SERVING A SEPARATE SOLID FUEL
BURNING APPLIANCE.
This appliance is designed to be attached to
two 3" (76mm) co-linear aluminium flex running
the full length of the chimney. See the Venting
Arrangements on next page for minimum and
maximum heights.
Required Parts:
Part #
Description
946-529
Co-linear DV Vertical
Termination Cap
948-305
3" Flex - 35 ft.
946-563
Co-Axial to Co-Linear Adapter Kit
which contains the following:
Co-linear Flex Adapter
Outer Pipe
Inner Pipe Adapter
Alternate Approved Caps
46dva-VC
Vertical Termination Cap
46dva-VCH High Wind Cap
46dva-GK
3" Co-linear Adapter with flashing
NOTE:
See detailed venting arrangements,
vertical terminations, co-linear flex system
into masonry fireplaces in this manual.
|
54
Grandview® G800EC Gas Fireplace
Masonry chimneys may take various contours which the flexible liner will accommodate. However,
keep the flexible liner as straight as possible, avoid unnecessary bending.
The Air Intake pipe must be attached to the inlet air collar of the termination cap.
#948-305 (35 ft)
Outer
Pipe
with Kit#
946-563
Pipe Length
Rigid Pipe Adapter
# 510-994
Co-linear DV
Vertical Termination
Cap # 946-529
A maximum
of two certified
joiner kits
may be used
per length.
Exhaust
Flue
90 Degree
Elbow
Inner Pipe
Adapter
with Kit#
946-563
Flex Liner
Air Intake
Co-Linear
Flex
Adapter
with Kit#
946-563