Exposed Shower Control; Rear Supplies - Mira Discovery Installation And User Manual

Shower valve
Table of Contents

Advertisement

Exposed Shower Control

1. Rear Supplies

1.1 Use the Installation Template to mark
the positions of the holes for the
Backplate and the pipe centres.
Note! Allow a minimum of 150 mm
either side of the Shower Control, to
allow the hot and cold inlet
Compression Nuts to be tightened
with the Spanner supplied.
1.2 For solid walls drill the Backplate holes
with a 6 mm drill and fit the Wall Plugs
(supplied). For other types of wall
structure
(not supplied) may be required.
1.3 Drill the supply pipe holes at 153 mm
centres.
1.4 Recess the wall to allow for the
concealing plates, 32 mm diameter
x 10 mm deep.
1.5 Fit the supply pipework (Hot - Left,
Cold - Right). The pipework must
project 18 mm from the finished wall
surface at 153 mm centres (use the
installation template as a guide).
Note! If the connections are reversed,
complete the installation then refer to
section: 'Reversed Inlet Supplies'
before commissioning.
1.6 Loosen the Grubscrew with the
2.5 mm hexagon key (supplied) and
remove the Backplate from the
Shower Control.
1.7 Secure the Backplate to the wall using
the Fixing Screws (supplied).
Note! The Grubscrew should be at the
bottom.
1.8 Fit the Concealing Plates.
Note! Apply silicone sealant to the
back face of the flange.
For latest prices and delivery to your door visit MyTub Ltd - www.mytub.co.uk - info@mytub.co.uk 0844 556 1818
alternative
fixings
Template
10 mm depth x Ø32 mm
for Concealing Plates
Shower Control
Backplate
Apply Silicone Sealant
13
Wall Plugs
153 mm
18 mm
Securing
Screws
Grubscrew
Concealing Plate